The CND310 series Electricity Special UPS system consisting of system cabinet, DBW bypass stabilized cabinet, and PDU feeder cabinet; CONSNANT designs exclusively for power plant, transformer substation, and distribution substation according to the development requirement of China Power. It possesses on-line double conversion and zero transfer function. It can be mainly applied for power system telemechanics, PTU, power line carrier, power system monitoring and so on. After being isolated and filtered by regulator, Single-phase 220V or three-phase 380V can provide stable power for load through inverter when the AC is normal. If the failure of AC power grid supply or a power cut occurs, the backup of DC power system can invert to supply electricity through the reverse diode. If the DC Power System is under voltage or cut off, the static switch will turn to bypass automatically. When the AC power is recover, the static switch will turn to AC power automatically. If the inverter is overloaded or fault, the system will turn to bypass and indicates a warning signal at the same time.
Features:
Adopt full digital control technology
Intelligent detection and monitoring function
Digitally control the static switching with zero switch
Full isolation between input and output
Super low output zero earth voltage
DC UPS isolated with utility power Compatible with the DC
power system and isolated with utility power completely
Cubicle design with the power standard both indication and
cabinet (Can be customized according to customer demands)
Multifunctional protection for over voltage, under voltage,
over current, short circuit and over temperature and so on.
Large-screen LCD monitor with Chinese and English operation
interface
Ultralong 256 event record, user-friendly analysis and
management to the situation of the power supply (touch screen
optional)
Static bypass has a strong anti-overload capability
Model Number
10KVA
15KVA
20KVA
30KVA
40KVA
Rating capacity
8 KW
12 KW
16 KW
24 KW
32 KW
Rating voltage
220VAC Single Phase (6-20KVA) / 380VAC Three Phases
AC input
Voltage range
±25%
Frequency range
50/60Hz±10%
Soft start
0 - 100% 5 seconds
Power Factor
0.95(with input filter)
Bypass input
Permitted voltage
range
±15%
Frequency range
50/60Hz±5%
Output
Voltage accuracy
220V±1%(steady load) 220V±3%( fluctuating load)
Permitted Frequency
range
50/60Hz±0.05Hz(powered by battery)
Power factor
0.8
Waveform Distorition
Linearload<2%, non linear load<4%
Dynamic load
voltage transients
<5%
Crest factor(lpeak/
lrms)
3:01
Overload capacity
Normal in 110% load, 125% for 10min
Efficiency
Double conversion mode: 94%; ECO mode: 98%
DC
Battery voltage
220V; (10-40KVA 110V is optional)
Cutoff voltage
185V
Maximum discharge
current
36A
55A
73A
109A
145A
Panel display
LCD
Chinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge
current, fault display , warning
Environment
Temperature
0ºC-40 ºC
Humidity
0-95%(no condensing)
Storage temperature
-25 ºC—55 ºC
Altitude
<1500m
Physical features
Weight(KG)
Net
230
258
350
400
480
Gross
250
285
380
425
500
Dimesion
W X D X H mm
800×600×2260
800×800×2260
Optional
RS485/SNMP/ Harmonic compensation cabinet/Input and output isolation cabinet/Lightning protection device/Bypass stablelized cabinet/
Customized appearance and size
Model Number
50KVA
60KVA
80KVA
100KVA
Rating capacity
40 KW
48 KW
64 KW
80 KW
Rating voltage
220VAC Single Phase (6-20KVA) / 380VAC Three Phases
AC input
Voltage range
±25%
Frequency range
50/60Hz±10%
Soft start
0 - 100% 5 seconds
Power Factor
0.95(with input filter)
Bypass input
Permitted voltage
range
±15%
Frequency range
50/60Hz±5%
Output
Voltage accuracy
220V±1%(steady load) 220V±3%( fluctuating load)
Permitted Frequency
range
50/60Hz±0.05Hz(powered by battery)
Power factor
0.8
Waveform Distorition
Linearload<2%, non linear load<4%
Dynamic load
voltage transients
<5%
Crest factor(lpeak/
lrms)
3:01
Overload capacity
Normal in 110% load, 125% for 10min
Efficiency
Double conversion mode: 94%; ECO mode: 98%
DC
Battery voltage
220V; (10-40KVA 110V is optional)
Cutoff voltage
185V
Maximum discharge
current
181A
218A
291A
364A
Panel display
LCD
Chinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge
current, fault display , warning
Environment
Temperature
0ºC-40 ºC
Humidity
0-95%(no condensing)
Storage temperature
-25 ºC—55 ºC
Altitude
<1500m
Physical features
Weight(KG)
Net
580
650
900
950
Gross
600
675
925
988
Dimesion
W X D X H mm
800×800×2260
800×1200×2260
Optional
RS485/SNMP/ Harmonic compensation cabinet/Input and output isolation cabinet/Lightning protection device/Bypass stablelized cabinet/
Customized appearance and size