Main parameters
Model
HT4830S80-145
HT4840S80-145
HT4850S80-145
HT4825U80-145
HT4830U80-145
HT4835U80-145
Mains mode
Rated input voltage
220/230Vac
110/120Vac
Input voltage range
(170Vac~280Vac) ±2%
(90Vac-280Vac)±2%
(90Vac~140Vac) ±2%
Frequency
50Hz/ 60Hz (automatic detection)
Frequency range
47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Circuit breaker
Efficiency
>95%
Conversion time
10ms (typical)
(bypass and inverter)
AC backflow protection
Yes
Maximum bypass overload current
40A
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power (VA)
3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output power (W)
3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Power factor
1
Rated output voltage (Vac)
230Vac(200/208/220/240Vac Settable)
120Vac(100/105/110Vac Settable)
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz
60Hz ± 0.3Hz
Efficiency
>92%
>91%
Overload protection
(102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
(125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
Load>150% ±10%: Report error and turn off output after 5 seconds;
(102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
(110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
Load>125% ±10%: Report error and turn off output after 5 seconds;
Peak power
6000VA
8000VA
10000VA
4000VA
4500VA
5000VA
Loaded motor capacity
2HP
3HP
4HP
1HP
2HP
2HP
Output short circuit protection
Circuit breaker
Bypass circuit breaker specification
63A
Rated battery input voltage
48V (minimum starting voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery...LCD screen can be set)
Eco mode
Load ≤ 50W
AC charging
Battery type
Lead acid or lithium battery
Maximum charge current
0-60A
0-40A
Charge
current error
± 5Adc
Charge voltage range
40 - 58Vdc
40 - 60Vdc
Short circuit protection
Circuit breaker
Circuit breaker specification
(AC IN) 63A/(BAT) 125A
Overcharge protection
Alarm and turn off charging in 1 minute.
PC charge
Maximum PV open circuit voltage
145Vdc
PV operating voltage range
60-145Vdc
MPPT voltage range
60-115Vdc
Battery voltage range
40-60Vdc
Maximum output power
4200W
PV charge current range (settable)
0-80A
Charge short circuit protection
BAT circuit breaker and fuse
Wiring protection
Reverse polarity protection
Hybrid charging Max charger current specifications (AC charger+PV charger)
Max charger current(can be set)
0-140A
0-120A
Certified specification
Specification certification
CE(EN62109)
EMC certification level
EN61000, C2
Operating temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
RH range
5% to 95% (conformal coating protection)
Noise
≤60dB
Heat dissipation
Forced air cooling, adjustable air speed
Communicat ion interface
USB/RS485 (WiFi/GPRS)/Dry Node Control
Dimensions (L*W*D)
482*425*133mm
Weight (kg)
13.3
Features
It adopts full digital voltage and current double closed loop control, combined with advanced SPWM technology to output pure sine wave.
Two output modes: mains bypass and inverter output enable uninterrupted power supply.
4 charging modes are available for choice: only PV, mains priority, PV priority, and hybrid charging.
AdvancedMPPT technology with efficiency up to 99.9%.
LCD screen design, with 3 LED indicators, for dynamic display of system data and run status.
ON/OFF rocker switch controls AC output.
Power saving mode reduces no-load loss.
Intelligent variable speed fan ensures efficient heat dissipation, and thereby extends system life.
It comes with double lithium battery activation modes: mains and PV, and supports lead-acid battery and lithium battery access.
Multiple protections provide 360 ° all-round protection for the system.
Complete protections include multi-electrical appliance air switch short circuit protection, overvoltage and undervoltage protection, overload protection, back-flow protection, etc.
Horizontal installation facilitates cabinet combination installation.
Lithium battery can be activated by both mains and PV panel.