160-250KVA Low Frequency Online UPS | CNG330

We specialize in providing backup power solutions for various applications

Home > Products > UPS(Uninterruptible Power Supply) > Low Frequency Online UPS > 160-250KVA Low Frequency Online UPS | CNG330

160-250KVA Low Frequency Online UPS | CNG330

Model Number: CNG330 160-250KVA

Nominal Capacity: 160 – 250KVA

Nominal Voltage: 380/400/415VAC

Maximum Input Voltage Range: +-20%

Nominal Frequency: 50/60HZ

Application field

  • IDC
  • Hospital
  • traffic control field
  • Bank, Securities Clearing Center
  • Control applications in industrial processes
  • Medium-scale network management system, billing center

Additional information

Description

Model 160KVA 200KVA 250KVA
Capacity 128KW 160KW 250KW
Input
Rated voltage 400Vac three-phase
Voltage range 380/400/415VAC (+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%)Bypass synchronization tracking
Rectifying pulse number 6/12 pulse rectification 12 pulse rectification
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage(VDC) 384
Battery quantity(section) Standard with 32(30~34, can be set through the LCD panel)
Standard 40 knots(38~42 knots, can be set by LCD panel)
Output
Power factor 0.8/0.9
Voltage(V) L-N:220±1%  L-L:380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(Hz) Normal power, tracking the frequency of power , Grid abnormal. 50±0.2%
Transfer time(ms) 0
Parallel operation mode(parallel type) 8 parallel machine
Waveform distortion Linear loadTHD<3%; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150% full load 1 minute and then switch to bypass power supply, after reducing the load can automatically restore the inverter
Crest factor >3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function Provides dry contract communication and RS232/RS485, Optional SNMP option to achieve intelligent monitoring of UPS
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage,input frequency, three-phase output voltage, load, battery voltage, battery charge and discharge current,etc.
Display LCD 7°touch screen display
The audio noise(db) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature(℃) 0~40
Humidity 0~95%, non-condensing
Electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 1200*850*1900
Weight(kg) 2.48

 

Features

High intelligence and reliable power supply:

It provides maximum protection for vital mission-critical networks, security applications (electro-medical), and industrial applications thanks to its outstanding mechanical and electrical design.

The load is powered continuously by the inverter with a filtered, stabilized, and regulated sine wave supply. The input and output EMI filter considerably increase the immunity of the load to mains disturbances and surges.

The CNG330 series UPS uses on-line double conversion technology (VFI) with an isolation transformer on the inverter output.

It is supplied with Watch & Save 3000 software as standard and can be remotely monitored

using the Power Net Guard system from anywhere in the world. Additional battery extension packs allow the standard battery routine to be extended up to several hours.

 

Minimum impact on supplies easy sources:

Input current distortion <4% for the CNG330 with a filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enables CNG330 to deliver maximum performance levels regardless of the installation environment. With these input features CNG330 can achieve significant savings in terms of sizing and power supply sources isolation transformers and generators over less sophisticated power systems.

 

Maximum battery care:

Battery deep discharge protection;

Temperature compensating charger;

Built-in automatic and manual battery test feature.

 

Simple to install:

Capability to install the UPS into any distribution system(neutral not required on rectifier input);

Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation (Necessary on UPS without an output transformer).

 

High reliability:

Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting, drives, and industrial processes) and an isolation transformer on the inverter output;

Full microprocessor control with no-break static and manual bypasses;

IGBT technology.

 

Other characteristics

0.8 power factor make CNG330 suitable for powering ICT and Industrial loads;

High-level diagnostics: event log with 128 messages, states, measurements, and alarms – available from the built-in LCD with several languages;

 

Back feed protection: to avoid energy feeding back into the mains supply cause a fault to occur.

 

Maximum reliability and availability

Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continues to work in parallel even if one of the interconnecting communication cables is disconnected (CLOSED LOOP).

 

Low consumption level:

CNG330 can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.

 

 

Advanced communication

 

Compatible with TeleNetGuard for remote maintenance;

Advanced, multi-platform communication for all operating systems and network environments: Watch & Save 3000 monitoring and shut-down software included, with SNMP agent, for Windows 2008, Vista,2003, XP; Mac OS X, Linux, Novell, and most popular Unix operating systems;

 

The UPS is supplied with a cable for direct connection to the PC(Plug and Play);

RS232 double Serial port; Installation slot for an Emergency Power Off (EPO) interface to allow the UPS to be switched off remotely in an emergency;

Generator interface: enables desynchronization of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charge.

 

Expandability:

The units can be connected in parallel up to 8 units to increase power availability or redundancy. The single

module or the system can be expanded at any time to suit power requirements without influencing the initial investment.

Releated

SC HF OFF-GRID INVERTER

SC HF OFF-GRID INVERTER PERFORMANCE AND FUNCTIONALITY Pure sine wave off-grid type optical storage integrated machine Output power factor1 Up to 6 units can be Paralleled Wide PV input voltage range (120-450VDC) It can work normally without a battery Built-in 100A MPPT solar charger The battery balancing feature optimizes battery performance and extends the life Built-in dust screen for use in harsh environments SCENARIOS Mainly used in household solar power generation, used to drive household small power load of electrical appliances.   Model SC HF 3500-24 SC HF 5500-48 Rated power 3500VA/3000W 5500VA/5500W Input Voltage 230VAC Voltage range 170-280VAC(suitable for personal   computers) 90-280VAC(Suitable for household   appliances) Frequency range 50Hz/60Hz(Automatic adaptation) Output Grid voltage regulation(battery mode) 230VAC±5% Surge power 7000VA 11000VA Efficiency >93.6% Switch time 10ms Waveform Pure sine wave Battery Battery voltage 24VDC 48VDC Float charge voltage 27VDC 54VDC Overcharge protection 33VDC 63VDC PV Charge &AC Charge PV maximum open-circuit voltage 500VDC 500VDC PV maximum power 5500W 5500W Maximum grid 80A 80A MPPT operating voltage range 120VDC-450VDC 120VDC-450VDC PV maximum 100A 100A charge current Physical properties Size 300*110*462 Net weight (kg) 10.5 11.5 Communication interface RS232 Environment Humidity Relative humidity (non-condensing) Operating temperature -10℃-50℃ Storage temperature -15℃-60℃

Hybrid PV Energy Storage Solar Charger Inverter

Main parameters Model HT4830S80-145 HT4840S80-145 HT4850S80-145 HT4825U80-145 HT4830U80-145 HT4835U80-145 Mains mode Rated input voltage 220/230Vac 110/120Vac Input voltage range (170Vac~280Vac) ±2% (90Vac-280Vac)±2% (90Vac~140Vac) ±2% Frequency 50Hz/ 60Hz (automatic detection) Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz); Overload/short circuit protection Circuit breaker Efficiency >95% Conversion time 10ms (typical) (bypass and inverter) AC backflow protection Yes Maximum bypass overload current 40A Inverter mode Output voltage waveform Pure sine wave Rated output power (VA) 3000(2600/2700 /3000) 4000(3480/360 3800/4000) 5000(4350/4500 /4800/5000) 2500(2000/2180 /2290) 3000(2500/2600 /2750) 3500(2900/3000 /3200) Rated output power (W) 3000(2600/2700 /3000) 4000(3480/360 3800/4000) 5000(4350/4500 /4800/5000) 2500(2000/2180 /2290) 3000(2500/2600 /2750) 3500(2900/3000 /3200) Power factor 1 Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable) 120Vac(100/105/110Vac Settable) Output voltage error ±5% Output frequency range (Hz) 50Hz ± 0.3Hz 60Hz ± 0.3Hz Efficiency >92% >91% Overload protection (102%<load<125%) ±10%: Report error and turn off output after 5 minutes; (125%<load<150%) ±10%: Report error and turn off output after 10 seconds; Load>150% ±10%: Report error and turn off output after 5 seconds; (102%<load<110%) ±10%: Report error and turn off output after 5 minutes; (110%<load<125%) ±10%: Report error and turn off output after 10 seconds; Load>125% ±10%: Report error and turn off output after 5 seconds; Peak power 6000VA 8000VA 10000VA 4000VA 4500VA 5000VA Loaded motor capacity 2HP 3HP 4HP 1HP 2HP 2HP Output short circuit protection Circuit breaker Bypass circuit breaker specification 63A Rated battery input voltage 48V (minimum starting voltage 44V) Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) Eco mode Load ””≤ 50W AC charging Battery type Lead acid or lithium battery Maximum charge current 0-60A 0-40A Charge current error ± 5Adc Charge voltage range 40 – 58Vdc 40 – 60Vdc Short circuit protection Circuit breaker Circuit breaker specification (AC IN) 63A/(BAT) 125A Overcharge protection Alarm and turn off charging in 1 minute. PC charge Maximum PV open circuit voltage 145Vdc PV operating voltage range 60-145Vdc MPPT voltage range 60-115Vdc Battery voltage range 40-60Vdc Maximum output power 4200W PV charge current range (settable) 0-80A Charge short circuit protection BAT circuit breaker and fuse Wiring protection Reverse polarity protection Hybrid charging Max charger current specifications (AC charger+PV charger) Max charger current(can be set) 0-140A 0-120A Certified specification Specification certification CE(EN62109) EMC certification level EN61000, C2 Operating temperature range -15°C to 55°C Storage temperature range -25°C ~ 60°C RH range 5% to 95% (conformal coating protection) Noise ≤”60dB Heat dissipation Forced air cooling, adjustable air speed Communicat ion interface USB/RS485 (WiFi/GPRS)/Dry Node Control Dimensions (L*W*D) 482*425*133mm Weight (kg) 13.3 Features It adopts full digital voltage and current double closed loop control, combined with advanced SPWM technology to output pure sine wave. Two output modes: mains bypass and inverter output enable uninterrupted power supply. 4 charging modes are available for choice: only PV, mains priority, PV priority, and hybrid charging. AdvancedMPPT technology with efficiency up to 99.9%. LCD screen design, with 3 LED indicators, for dynamic display of system data and run status. ON/OFF rocker switch controls AC output. Power saving mode reduces no-load loss. Intelligent variable speed fan ensures efficient heat dissipation, and thereby extends system life. It comes with double lithium battery activation modes: mains and PV, and supports lead-acid battery and lithium battery access. Multiple protections provide 360 ° all-round protection for the system. Complete protections include multi-electrical appliance air switch short circuit protection, overvoltage and undervoltage protection, overload protection, back-flow protection, etc. Horizontal installation facilitates cabinet combination installation. Lithium battery can be activated by both mains and PV panel.

1-3KVA Rack Mount UPS

1-3KVA Rack-Mounted Online UPS Datasheet Feature: Zero Transfer time True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues DSP Digital Control Based Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply Ultra Wide Input Mains range Strong compatible with ultra with electric environment, stay well with ultra wide range mains of  90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life Best Loading Capability Up to 0.9 Output Power Factor, 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application Genset Compatible Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment. High Input power factor Thanks to digital controlled  PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer Reliable design Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion Open to customization Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system   Specification:   Model CNH110-1KR CNH110-1KRS CNH110-2KR CNH110-2KRS CNH110-3KR CNH110-3KRS Capacity VA/W 1kVA/800W 2kVA/1.6kW 3kVA/2.4kW Topology Double Conversion Online UPS Phase Single Phase Input Single Phase Output Mains Input Wiring L/N+PE Rated Voltage 208/220/230/240VAC Voltage Range 90~300VAC Frequency Range 40Hz-70Hz Input Power Factor ≥0.99 AC Output Wiring L/N+PE Output Voltage 208/220/230/240VAC Voltage Regulation ±1% Output Frequency 50/60±4Hz(Sync   Mode) / 50/60Hz±0.1%(Free Run) Waveform Pure Sine Wave Distortion <2%(Linear Load) (THDV%) <7%(None-Linear Load) Over load capability 1Min@105%~125%Rated   Load 30Sec.@125%~150%Rated Load 0.5Sec.@>150%Rated Load Efficiency AC/AC Mode 0.88 0.89 0.9 DC/AC Mode 0.86 0.87 0.88 Battery&Charge Rated Battery Voltage 24VDC Internal 36VDC External 48VDC Internal 72VDC External 48VDC Internal 96VDC External Battery Capacity 12V/7AH X2pcs External Battery Depends 12V/7AHx4pcs External Battery Depends 12V/9AH x4pcs External Battery Depends Backup Time >6mins @ Half Load >6mins @ Half   Load >6mins @ Half Load Charging Current Standard Model   with Internal Battery:1A Long Backup Time Model :4A Physical Chassis Style Rack-Mounted Rack Dimension 1KR/1KSR/2KR/2KSR/3KSR: 438mm(W) x 88mm(2U)(H) x 360mm(D) 3KR: 438mm(W) x 88mm(2U)(H) x   500mm(D) Include Internal Battery Weight (kg) 13 8.5 18.5 11.5 21.9 12 HMI LCD DISPLAY Input Mains   Voltage, Frequency, Load level, Operation Mode, Health Status Standards Communication Interface 1. RS232 PORT Optional Extension Card 2. NMC   Card: Support remote monitor the UPS   via Smart Phone APP, Web page, PC   Monitor Software , Support Server / NAS shutdown 3. MODBUS Card, 4. USB Card 5. Relay Card (Needs assembly according to order request before shipping Operating Environment   Endurance Temperature range -10~50oC Relative Humidity 0-98%(Non-condensing) Acoustics Noise <55dB @ 1 meters UPS Outlook③ Front View CNH110-1KR(S)/CNH110-2KR(S)/CNH110-3KR(S) 2U Rack-Mounted UPS   Rear View CNH110-1KR(S)/CNH110-2KR(S) 2U Rack-Mounted UPS Rear Panel CNH110-3KR(S) 2U Rack-Mounted UPS Rear Panel Note: ① Battery Capacity and voltage is open to customization ② Dimension might vary for different bezel ③ The socket and terminal configuration on the rear panel may be different for countries or regions according to order ④ More parameter customization,please contact sales representative

6-10KVA Rack Mount UPS

6~10kVA ONLINE UPS – Rack Mount Style Datasheet Feature: Zero Transfer time True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues. DSP Digital Control Based Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply Three Level Inverter Low harmony noise, high efficiency , excellent loading capability Ultra Wide Input Mains range Strong compatible with ultra with electric environment, stay well with ultra wide range mains of 90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life Best Loading Capability Up to 0.9 Output Power Factor , 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application Genset Compatible Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment. High Input power factor Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer Reliable design Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion. Open to customization Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system Specification: Model CNH110-6KRS CNH110-10KRS Capacity VA/W 6kVA/5.4kW 10kVA/9kW Topology Double Conversion Online UPS Phase Single Phase Input Single Phase Output Mains Input Wiring L/N+PE Rated Voltage 208/220/230/240Vac Voltage Range 90~300VAC Frequency Range 40Hz-70Hz Input Power Factor ≥0.99 AC Output Wiring L/N+PE Output Voltage 208/220/230/240VAC Voltage Regulation ±1% Output Frequency 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run) Waveform Pure Sine Wave Distortion <2%(Linear Load) (THDV%) <7%(None-Linear Load) Over load capability 10Min@105%~125%Rated   Load 60Sec.@125%~150%Rated Load 0.5Sec.@>150%Rated Load Efficiency AC/AC Mode >93% DC/AC Mode >91% Battery&Charge Rated Battery Voltage 192/240VDC External Battery Battery Capacity External Battery Depends Backup Time External Battery Depends Charging Current Long Backup Time Model :4A Physical Chassis Style Rack-Mounted Rack Dimension UPS: 438mm(W) x 88mm(2U)(H) x 500mm(D) without Internal Battery Battery Pack: 438mm(W) x 88mm(2U)(H)   x500mm(D) Weight (kg) C6KRS :   14.6kg C10KRS: 15.0kg Battery Pack: 7AHx16pcs: 39kg HMI LCD DISPLAY Input Mains Voltage, Frequency, Load level, Operation   Mode, Health Status Standards Communication Interface 1. RS232 PORT Optional Extension Card 2. NMC   Card: Support remote monitor the UPS   via Smart Phone APP, Web page, PC   Monitor Software , Support Server / NAS shutdown 3. MODBUS Card, 4. USB Card 5. Relay Card (Needs assembly   according to order request before shipping Operating Environment   Endurance Temperature range -10~50oC Relative Humidity 0-98%(Non-condensing) Acoustics Noise <55dB @ 1 meters UPS Outlook③   Front View CNH110-6KRS~CNH110-10KRS 2U Rack UPS   CCNH110-6KRS~CNH110-10KRS Rack UPS Rear Panel Note: ① Battery Capacity and voltage is open to customization ② Dimension might vary for different bezel ③ The socket and terminal configuration on the rear panel may be different for countries or regions according to order ④ More parameter customization,please contact sales representative

6-10KVA Tower UPS

6~10kVA ONLINE UPS – Tower Style Datasheet Feature: Zero Transfer time True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues. DSP Digital Control Based Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply Three Level Inverter Low harmony noise, high efficiency , excellent loading capability Ultra Wide Input Mains range Strong compatible with ultra with electric environment, stay well with ultra wide range mains of  90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life Best Loading Capability Up to 0.9 Output Power Factor , 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application Genset Compatible Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment. High Input power factor Thanks to digital controlled  PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer Reliable design Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion. Open to customization Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system     Specification:   Model CNH110-6K CNH110-6KS CNH110-10K CNH110-10KS Capacity VA/W 6kVA/5.4kW 10kVA/9kW Topology Double Conversion Online UPS Phase Single Phase Input Single Phase Output Mains Input Wiring L/N+PE Rated Voltage 208/220/230/240Vac Voltage Range 90~300VAC Frequency Range 40Hz-70Hz Input Power Factor ≥0.99 AC Output Wiring L/N+PE Output Voltage 208/220/230/240VAC Voltage Regulation ±1% Output Frequency 50/60±4Hz(Sync   Mode) / 50/60Hz±0.1%(Free Run) Waveform Pure Sine Wave Distortion <2%(Linear Load) (THDV%) <7%(None-Linear Load) Over load capability 10Min@105%~125%Rated Load 60Sec.@125%~150%Rated Load 0.5Sec.@>150%Rated Load Efficiency AC/AC Mode >93% DC/AC Mode >91% Battery&Charge Rated Battery Voltage 144/192VDC Internal/ 192/240VDC External 192VDC Internal 192/240VDC External Battery Capacity 12V/7AHx12Pcs/ 12V/7AHx16Pcs External Battery Depends 12V/7AHx16Pcs/ 12V/9AHx16Pcs External Battery Depends Backup Time >6mins @ Half Load >6mins @ Half Load Charging Current Standard Model   with Internal Battery:1A Long Backup Time Model :4A Physical Chassis Style Tower Tower Dimension C6KS, C10kS: 190(W)X340(H)x534(D)mm C6K-12BAT:190(W)X360(H)x534(D)mm C6K-16BAT, C10K: 190(W)X456(H)x534(D) Weight (kg) C6K-12BAT:   37kg C6K-16BAT: 46.5kg 14.8kg C10K-7AHx16: 47.8kg C10K-9AHx16: 54.2kg 16kg HMI LCD DISPLAY Input Mains   Voltage, Frequency, Load level, Operation Mode, Health Status Standards Communication Interface 1. RS232 PORT Optional Extension Card 2. NMC Card: Support remote monitor the UPS via Smart   Phone APP, Web page, PC Monitor   Software , Support Server / NAS shutdown 3. MODBUS Card, 4. USB Card 5. Relay Card (Needs assembly according to order request before shipping Operating Environment   Endurance Temperature range -10~50oC Relative Humidity 0-98%(Non-condensing) Acoustics Noise <55dB @ 1 meters UPS Outlook③   Front View CNH110-6KS/10KS/ CNH110-6K-12BAT Bezel CNH110-6K/10K-16BAT Bezel Rear Panel CNH110-6K(S)~CNH110-10K(S) Rear Panel Note: ① Battery Capacity and voltage is open to customization ② Dimension might vary for different bezel ③ The socket and terminal configuration on the rear panel may be different for countries or regions according to order ④ More parameter customization,please contact sales representative

1-3KVA Tower UPS

1-3KVA Online UPS Data-sheet  Feature: Zero Transfer time True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues DSP Digital Control Based Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply Ultra Wide Input Mains range Strong compatible with ultra with electric environment, stay well with ultra wide range mains of  90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life Best Loading Capability Up to 0.9 Output Power Factor, 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application Genset Compatible Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment. High Input power factor Thanks to digital controlled  PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer Reliable design Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion Open to customization Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system   Specification: Model CNH110-1K CNH110-1KS CNH110-2K CNH110-2KS CNH110-3K CNH110-3KS Capacity VA/W 1kVA/900W 2kVA/1.8kW 3kVA/2.7kW Topology Double Conversion Online UPS Phase Single Phase Input Single Phase Output Mains Input Wiring L/N+PE Rated Voltage 208/220/230/240VAC Voltage Range 90~300VAC Frequency Range 40Hz-70Hz Input Power Factor ≥0.99 AC Output Wiring L/N+PE Output Voltage 208/220/230/240VAC Voltage Regulation ±1% Output Frequency 50/60±4Hz(Sync   Mode) / 50/60Hz±0.1%(Free Run) Waveform Pure Sine Wave Distortion (THDV%) <2%(Linear Load) <7%(None-Linear Load) Over load capability 1Min@105%~125%Rated   Load 30Sec.@125%~150%Rated Load 0.5Sec.@>150%Rated Load Efficiency AC/AC Mode 88% 89% 90% DC/AC Mode 86% 87% 88% Battery&Charge Rated Battery Voltage ① 24VDC Internal 36VDC External 48VDC External 72VDC External 72VDC External 96VDC Battery Capacity 12V/7AHx2pcs External Battery Depends 12V/7AHx4pcs External Battery Depends 12V/7AHx6pcs External Battery Depends Backup Time >6mins @ Half Load >6mins @ Half Load >6mins @ Half Load Charging Current Standard Model   with Internal Battery:1A Long Backup Time Model :4A Physical Chassis Style Tower Tower Dimension 1KS:   145(W)X220(H)x250(D)mm 1K, 2KS: 145(W)X220(H)x318(D)mm 2K:145(W)X220(H)x390(D)mm 3K/3KS: 190(W) x 318(H) x 368(D)mm Weight (kg) 8.9 4.2 14 5.9 21.6 8.3 HMI LCD DISPLAY Input   Mains Voltage, Frequency, Load level, Operation Mode, Health Status StandardsCommunication Interface 1.    RS232 PORT Optional Extension Card 2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown 3. MODBUS Card, 4. USB Card 5. Relay Card (Needs assembly according to order request before shipping Operating   EnvironmentEndurance Temperature range -10~50oC Relative   Humidity 0-98%(Non-condensing) Acoustics Noise <55dB @ 1 meters   UPS Outlook③ Front View CNH110-1K(S)  Bezel with 4 Button CNH110-2K(S) /CNH110-3K(S) Bezel with 4 Button Rear View CNH110-1/2K CNH110-1KS/2KS CNH110-3K_HV Rear Panel CNH110-3KS_HV Rear Panel Note: ① Battery Capacity and voltage is open to customization ② Dimension might vary for different bezel ③ The socket and terminal configuration on the rear panel may be different for countries or regions according to order ④ More parameter customization,please contact sales representative
Previous
Next