Model Number: CNH330R 10-40KVA
Nominal Capacity: 10-40KW
Nominal Voltage: 380/400/415VAC
Input Voltage Range: 138~476VAC
Nominal Frequency: 40~70HZ
Item No :
CNH330R 10-40KVAOrder(MOQ) :
1 pcsPayment :
T/TProduct Origin :
ChinaColor :
BlackShipping Port :
ShenzhenLead Time :
1 weekWeight :
23-28.5 Kg
Description
This series UPS is a kind of three-in- three -out high frequency online UPS, it provides three specifications: The 10KVA, 15KVA, 20KVA, 30KVA and 40KVA. The products are modularized and adopt the N+X redundancy. It can flexibly increase the number of the UPS modules according to the load capacity which is convenient for flexible allocation and gradually investment.
The UPS can solve most of the power supply problems, such as blackout, over-voltage, under-voltage, voltage sudden drop, oscillating of decreasing extent, high voltage pulse, voltage fluctuation, surge, inrush current, harmonic distortion (THD), noise interference, frequency fluctuation, etc..
This UPS can be applied to different applications from computer device, automatic equipment, communication system to industry equipment.
Functions and Features
◆3Phase In/3Phase Out UPS
It is 3Phase In/3Phase Out high-density UPS system, of which input current is kept in balance. No unbalance problem might occur.
◆Digital Control
This series UPS is controlled by Digital Signal Processor(DSP); it increases reliability, performance, self-protection, self-diagnostics and so on.
◆Compact Design
This series UPS adopts compact design concept. The capacities are available for 10KVA, 15KVA, 20KVA, 30KVA and 40KVA.
◆Battery Configurable from 30 blocks to 50 blocks
The battery voltage of this series UPS can be configured at 30 blocks,32 blocks, 34 blocks, 36 blocks, 38 blocks, 40 blocks, 42 blocks, 44 blocks , 46 blocks, 48 blocks or 50 blocks according to your convenience.
◆Charging Current is configurable
Via setting tool, the user may set the capacity of the batteries as well as reasonable charging current as well as maximum charging current. Constant voltage mode, constant current mode or floating mode can be switched automatically and smoothly.
◆Intelligent Charging Method
The series UPS adopts advanced three-stage charging method—
1st stage: high current constant current charging to guarantee to charge back to 90%;
2nd-stage: Constant Voltage
In order to vitalize battery and make sure batteries are fully charged
3rd stage: floating mode.
With this 3-stage charging method, it extends the life of the batteries and guarantees fast charging.
◆LCD Display
With LCD plus LED displays, the user may easily get UPS status and its operational parameters, such as input/output voltage, frequency & load%, battery % and ambient temperature, etc..
◆Intelligent Monitoring Function
Via optional SNMP Card, you may remotely control and monitor the UPS.
◆EPO Function
The series UPS may be completely shut off when the EPO is pressed. REPO function(Remote EPO) is also available in this series UPS.
Technical Parameters
Capacity (VA/W) |
CNH330R 10-40KVA |
||
Input |
Phase |
3Phase/4Wires + Ground |
|
Rated Voltage |
380/400/415Vac |
||
Voltage Range |
138~476Vac |
||
Frequency Range |
40~70Hz |
||
Power Factor |
≥0.99 |
||
Bypass Voltage Range |
Max.voltage: +15%(optional +5%、+10%、+25% ) |
||
Current Harmonic |
≤3(100% linear load) |
||
Output |
Phase |
3Phase/4Wires + Ground |
|
Rated Voltage |
380/400/415Vac |
||
Power Factor |
0.9 |
||
Voltage Precision |
±1% |
||
Output Frequency |
Utility Mode |
±1%、±2%、±4%、±5%、±10% of the rated frequency(optional) |
|
Battery Mode |
(50/60±0.2)Hz |
||
Crest Factor |
3:1 |
||
Transfer Time |
Utility to Battery : 0ms Utility to bypass : 0ms (following) |
||
Overload Capacity |
Load≤110%,60min,≤125%,last 10min,≤150%last 1min,≥150% shut down UPS immediately |
||
THD |
≤2% with linear load |
||
Efficiency |
ECO mode≥98%;Normal mode≥95% |
||
Comunication Interface |
UPS module |
RS485、SNMP card(optional) |
|
Battery |
Voltage |
±180V/±192V/±204V/±216V/±228V/±240/±252/ ±264/±276/±288/±300Vdc optional |
|
Charge Current(A) |
UPS module |
Maximum current 10A |
|
Backup time |
Depends on the capacity of external batteries |
||
Operating Environment |
Temperature |
0℃~40℃ |
|
Humidity |
0~95% non condensing |
||
Storage temperature |
-25℃~55℃ |
||
Altitude |
< 1500m |
||
Other |
Unit Dimensions(W*H*D) |
UPS module |
485x130 x728mm |
Weight (Kg) |
UPS module |
23/25/25/26/28.5 |
|
Industry Standard |
CE,EN/IEC 62040-2,EN/IEC 62040-1-1 |
Tags :