Outdoor pole mount telecom power supply
Model Number:OD-TRS-24100/OD-TRS-48100
Nominal Capacity:24/48VDC 100A
Nominal Voltage: 220VAC/230VAC
Item No :
OD-TRS-24100/OD-TRS-48100Order(MOQ) :
10 pcsPayment :
T/TProduct Origin :
ChinaColor :
RAL7035Shipping Port :
ShenzhenLead Time :
2-3 weeksWeight :
99 KgTelecom Power System 24VDC/48VDC 100A
Telecom equipments, usually used in the remote and rugged areas. OD-TRS series power supply has unique features like high temperature resistance, water resistance, corrosion resistance, dust resistance, etc. It can provide these equipments reliable power supply under harsh conditions.
Besides, it has wide input voltage range and frequency range, can well adapt to the poor grid quality in these areas.
Features
• The OD-TRS series outdoor pole-mounted communication power system has a cost-effective,customizable rack-mounted supporting installation form.
• The system is composed of a rectifier part, a dynamic ring part, an ODF (optical fiber fusion splicing), a lithium battery part, and a power distribution part.
• At the same time the whole system can maintain high reliability and provide flexibility for future expansion.
• Based on the monitoring management function and power system monitoring function, equipped with appropriate sensors, the system can achieve environ-ment monitoring,provide lithium battery status information and system status information,and provide RS485, LAN communication interfaces.
• It can support MODBUS RTU,MODBUS ASCII,SNMP V1,V2,V3 protocols for unattended and remote monitoring.
Technical Parameters
Model | OD-TRS-24100(Integrated custom system) | OD-TRS-48100(Integrated custom system) |
System Capacity | 24V100A(One master and one backup) | 48V100A(One master and one backup) |
System Parameter | ||
Rate Voltage | 220/230/240VAC, Single phase in+Ground | |
Input Votage Range | 90~280Vac | 90~300Vac |
Input Frequency Range | 45~63Hz | 45~65Hz |
Rated Output Voltage | 24VDC | 48VDC |
Adjustable Voltage Range | 20V~29V | 42V~58V |
Stabilization Accuracy | ≤±1% | |
Output Current | 50A | |
Dynamic Response Recovery Time | ≥10ms | |
Input PF | ≥0.99 | |
Display | LED/LCD | |
Alarm | LLVD,BlVD alarm,Door opening alarm,Battery low, Mains failure,Module failure,Over temperature,Temperature and humidity alarm(Optional) |
|
Work Environment | -10~40℃ | |
Relative Humidity | Maximum 95%(Non-Condensing) | |
Working | <1000m. Power derate 1% for every 100m rise | |
Altitude | Above 1000m,maximum 4000m | |
Storage Temperature | -5~45℃ | |
Storage Relative Humidity | 0~90% | |
Cooling Mode | Fan cooling | |
Noise(1 meter) | 53~62dB | |
IP Class | IP55 | |
Incoming Line Mode | Bottom inlet | |
Maintenance Mode | Front | |
Power Distribution Part | Input with lightning protection: level Class I+ll, level 1+2, compound type; Output: 3 channels 24VDC/48VDC | |
Built-in ODF(Optional) | 12 LC-UPC duplex adapter connections and 241.5M long, LC/UPC taps, fiber type: G655.C(optional) | |
LCD Display | DC voltage, DC current, Charge/Discharge, Output voltage, Output current, Input voltage, Input frequency, System temperature, etc | |
Battery | ||
Battery Type | Lithium battery pack | |
Nominal Battery Voltage | 25.6VDC | 51.2VDC |
Battery Capacity | 100AH | 50AH |
Floating Charge Voltage | 27VDC | 56VDC |
Equalizing Charging Voltage | 28.8VDC | 58VDC |
Cut Off | 22VDC | 44VDC |
Communication | ||
Computer Interface | MODBUS TCP/IP, SNMP V2/V3, RJ45 Port(System and dynamic ring host monitoring) | |
Physical | ||
Weight | 99Kg | |
Dimension:W×D×H(mm) | 670*720*990 | |
Cabinet Material | SPCC-cold rolled steel (standard), Galvanized Steel /Stainless Steel/Aluminium (optional) |